Displaying 1 - 33 of 33 tests
AML Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are cCD3, cCD22, cCD79, CD11b, CD123, CD34, CD45, CD117, cMPO, and nTdT (10 markers).

Flow Cytometry
AML Follow-Up Flow Panel

Available as global and tech-only. Please provide clinical history including the time after treatment. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Clients who decline full phenotyping and order a global or push-to-global Follow-Up Panel are requested to provide details of the diagnosis by submitting at least one of the following: previous flow cytometry report, previous pathology report, and/or clinical history notes. Markers are cCD3, CD11b, CD13, CD14, CD16, CD19, cCD22, CD33, CD34, CD45, CD64, cCD79a, CD117, CD123, HLA-DR, cMPO, and nTdT (17 markers).

Flow Cytometry
B-ALL Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are cCD3, cCD22, cCD79a, CD10, CD19, CD34, CD45, cMPO, and nTdt (9 markers).

Flow Cytometry
B-ALL Follow-Up Flow Panel

Available as global and tech-only. Please provide clinical history including the time after treatment. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Clients who decline full phenotyping and order a global or push-to-global Follow-Up Panel are requested to provide details of the diagnosis by submitting at least one of the following: previous flow cytometry report, previous pathology report, and/or clinical history notes. Markers are cCD3, CD5, CD10, CD11c, CD19, CD20, cCD22, CD23, CD34, CD45, cCD79a, kappa, lambda, cMPO, and nTdT (15 markers).

Flow Cytometry
B-ALL MRD Flow Panel

Available as global test only. Markers are CD3, CD9, CD10, CD13/CD33, CD19, CD20, CD34, CD38, CD45, CD58, CD71, and Syto16 (13 markers; Syto16 is not reported). This panel can detect MRD at the 0.01% level.

Flow Cytometry
B-Cell Lymphoma Follow-Up Flow Panel

Available as global and tech-only. Please provide clinical history including the time after treatment. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Clients who decline full phenotyping and order a global or push-to-global Follow-Up Panel are requested to provide details of the diagnosis by submitting at least one of the following: previous flow cytometry report, previous pathology report, and/or clinical history notes. Markers are CD5, CD10, CD11c, CD19, CD20, CD23, CD45, FMC-7, kappa, and lambda.

Flow Cytometry
CD4/CD8 Ratio for BAL

Available as global test only for bronchoalveolar lavage (BAL) specimens. Markers are CD3, CD4, CD8, and CD45 (4 markers). This test is not for quantitative immune status monitoring. (Tech-only testing is not offered as this test does not have a separate professional component.)

Flow Cytometry
CD43/FMC-7 Companion Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD43, CD3, CD22, CD36, FMC-7 and CD45 (6 abs).

Flow Cytometry
CLL MRD Flow Panel

Available as global test only. Markers are CD3, CD5, CD19, CD20, CD22, CD43, CD45, CD79b, and CD81 (9 markers).

Flow Cytometry
CLL/Mantle Cell Companion Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD3, CD22, CD36, CD43, CD45, CD200, and FMC7 (7 markers). This panel is not for detection of minimal residual disease (MRD).

Flow Cytometry
DNA Ploidy/Cell Cycle Analysis – Heme

Available as a global test only. DNA stain is DRAQ5™ to determine S-phase cell cycle fraction and DNA index as indicators of DNA ploidy in fresh leukemia or lymphoma specimens. Two markers will be added for gating; which specific markers are used depends on the phenotype of the abnormal population.
Phenotyping requirement: If concurrent tech-only or global flow immunophenotyping was not done at NeoGenomics, client must submit a flow report showing the immunophenotype of abnormal cells or a description of the immunophenotype.
Indication note: Samples are only accepted from hematopoietic neoplasms for this test. Please see DNA Ploidy/Cell Cycle Analysis – POC/Solid Tumors for other indications.

Flow Cytometry
DNA Ploidy/Cell Cycle Analysis – POC/Solid Tumors

Available as a global test only. DNA stain propidium iodide (PI) is used to determine S-phase cell cycle fraction and DNA index as indicators of DNA ploidy. Products of conception (POC) and solid tumors are accepted for this test. Please see DNA Ploidy/Cell Cycle Analysis – Heme for other indications.

Flow Cytometry
Erythroid-Mega Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are cCD41, cCD61, CD13, CD34, CD45, CD71,  CD117, and CD235a (8 markers).

Flow Cytometry
Extended Leukemia/Lymphoma Panel - 31 markers

Available as global and tech-only. Markers are CD2, CD3, CD4, CD5, CD7, CD8, CD10, CD11b, CD11c, CD13, CD14, CD15, CD16, CD19, CD20, CD23, CD33, CD34, CD38, CD41, CD45, CD56, CD64, CD71, CD117, CD138, CD235a, FMC-7, HLA-DR, kappa, and lambda.

Flow Cytometry
Hairy Cell Leukemia (HCL) Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD11c, CD19, CD20, CD22, CD25, CD45, CD103, kappa, and lambda (9 markers).

Flow Cytometry
Hairy Cell Leukemia (HCL) Follow-Up Flow Panel

Available as global and tech-only. Please provide clinical history including the time after treatment. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Clients who decline full phenotyping and order a global or push-to-global Follow-Up Panel are requested to provide details of the diagnosis by submitting at least one of the following: previous flow cytometry report, previous pathology report, and/or clinical history notes. Markers are CD11c, CD19, CD20, CD22, CD25, CD45, CD103, kappa, and lambda.

Flow Cytometry
Hematogone Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD10, CD19, CD20, CD22, CD34, CD38, CD43, CD45, and cTdT (9 markers).

Flow Cytometry
High Sensitivity PNH Evaluation

Markers are CD14, CD15, CD24, CD45, CD59, CD64, CD235a (Glycophorin A), and FLAER. In validation studies, this assay was shown to detect RBC and granulocyte PNH clones with frequency down to 0.01%.

Flow Cytometry
Mast Cell Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD2, CD25, CD34, CD45, and CD117 (5 markers).

Flow Cytometry
MDS Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD11b, CD13, CD36, CD41, CD45, CD71, CD117,  CD123, and CD235a (9 markers).

Flow Cytometry
Monocyte Maturation Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers CD15, CD64, HLA-DR, CD13, CD11c, CD36, CD14, CD56, CD11b and CD45 (10 markers).

Flow Cytometry
Plasma Cell Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD19, CD20, CD38, CD45, CD56, CD117, CD138, cKappa, and cLambda (9 markers).

Flow Cytometry
Plasma Cell Follow-Up Flow Panel

Available as global and tech-only. Please provide clinical history including the time after treatment. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Clients who decline full phenotyping and order a global or push-to-global Follow-Up Panel are requested to provide details of the diagnosis by submitting at least one of the following: previous flow cytometry report, previous pathology report, and/or clinical history notes.  Markers are CD19, CD20, CD38, CD45, CD56, CD117, CD138, cKappa, and cLambda (9 markers).

Flow Cytometry
Sezary T-Cell Add-On Flow PanelAvailable as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD3, CD4, CD5, CD7, CD8, CD19, CD26, CD43, and CD45 (9 markers). Flow Cytometry
Standard Leukemia/Lymphoma Panel - 24 markers

Available as global and tech-only. Markers are CD2, CD3, CD4, CD5, CD7, CD8, CD10, CD11c, CD13, CD14, CD16, CD19, CD20, CD23, CD33, CD34, CD38, CD45, CD56, CD64, CD117, HLA-DR, kappa, and lambda.

Flow Cytometry
T&B Tissue Flow Panel

Stand-alone test. Markers are CD2, CD3, CD4, CD5, CD7, CD8, CD10, CD11c, CD19, CD20, CD23, CD34, CD38, CD45, CD56, kappa, and lambda (17 markers). 

Flow Cytometry
T-ALL Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD1a, CD3, CD7, CD11b, CD19, CD43, CD45, cMPO, and nTdT (9 markers).

Flow Cytometry
T-ALL Follow-Up Flow Panel

Available as global and tech-only. Please provide clinical history including the time after treatment. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Clients who decline full phenotyping and order a global or push-to-global Follow-Up Panel are requested to provide details of the diagnosis by submitting at least one of the following: previous flow cytometry report, previous pathology report, and/or clinical history notes. Markers are CD1a , CD2, CD3, cCD3, CD4, CD5, CD7, CD8, CD11b, CD19, CD38, CD43, CD45, CD56, cMPO, and nTDT (16 markers).

Flow Cytometry
T-Cell Lymphoma Follow-Up Flow Panel

Available as global and tech-only. Please provide clinical history including the time after treatment. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Clients who decline full phenotyping and order a global or push-to-global Follow-Up Panel are requested to provide details of the diagnosis by submitting at least one of the following: previous flow cytometry report, previous pathology report, and/or clinical history notes. Markers are CD2, CD3, CD4, CD5, CD7, CD8, CD19, CD38, CD45, and CD56.

Flow Cytometry
T-Cell Receptor/LGL Add-On Flow Panel

Available as global and tech-only. This add-on panel is available to clarify findings on samples currently having flow cytometry analysis at NeoGenomics and is not available for stand-alone testing. Markers are CD3, CD4, CD7, CD8, CD16, CD45, CD56, CD57, TCR alpha/beta, and TCR gamma/delta (10 markers).

Flow Cytometry
T-Cell Therapy Flow Panel

Available as global and tech-only. Available as stand-alone test (as described here) or as add-on to panels. Markers are CD3, CD4, CD7, CD8, CD25, CD26, CD30, CD45, CD52, and CD279 (10 markers).

Flow Cytometry
V-Beta T-Cell Clonality

Available as global test only. Markers are VB1, VB2, VB3, VB4, VB5.1, VB5.2, VB5.3, VB7.1, VB7.2, VB8, VB9, VB11, VB12, VB13.1, VB13.2, VB13.6, VB14, VB16, VB17, VB18, VB20, VB21.3, VB22, and VB23 (24 markers). Two additional T-cell markers are used to identify the population of interest and the markers vary from case to case.

Flow Cytometry
ZAP-70 Lymphoid Panel

Available as global and tech-only. Markers are CD3, CD5, CD19, CD45, and ZAP-70.

Flow Cytometry